F-124

F-124

INTERNAL REMOTE CONTROL TEST

(continued)

FIGURE F.45 - DISPLAY BOARD PLUG LOCATIONS

J17

J16

J15

J14 J13 J12 J11

J10

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Remove main input supply power to the

machine.

2. With the 3/8" nut driver, remove the 4

screws that hold the handle to the machine.

3. Remove the rubber gasket (cover seal) from

the lift bail.

4. With the 5/16" nut driver, remove the sheet

metal screws from the case top.

5. With the 5/16" nut driver, remove the

screws holding the right and left case sides.
Remove the case sides by lifting up and
out.

6. Perform

the

Capacitor Discharge

Procedure described earlier in this section
of the manual.

Before continuing with the
test procedure, perform the
capacitor discharge proce-
dure to avoid electric shock.

7. After you have completed the capacitor dis-

charge procedure for all four switch boards,
remove the PC board cover. Use the 5/16"
nut driver.

8. Remove the 5 leads (3 heavy and 2 small)

T1, T2, T3 from main input contactor CR1.
This is a safety precaution. It prevents high
voltage from being put on the machine dur-
ing the test. Wrap tape around the lead
ends to insulate them and prevent them
from touching.

9. Remove plug J30 from the protection

board. See Figure F.1 for location of the
board and plug J30.