Perform the internal remote, Control test, Troubleshooting & repair – Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B User Manual
Page 183: Internal remote control test, Warning
INTERNAL REMOTE CONTROL TEST
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if there is a fault in the circuitry that reads the control knob com-
mands of the K941-1 Remote Control Kit.
MATERIALS NEEDED
Volt/Ohmmeter (Multimeter)
5/16" Nut driver
3/8" Nut driver
Trigger Circuit Wiring Diagram – Figure F.46
WARNING
TROUBLESHOOTING & REPAIR
F-123
F-123
POWER WAVE 450
This procedure takes approximately 45 minutes to perform.