TROUBLESHOOTING & REPAIR

F-6

F-6

POWER WAVE 450

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Machine has no output – fans are
running – display is on – a “click-
ing” sound is heard coming from
the machine.

1. Turn power OFF immediately.

2. Check for proper input voltage

(per machine nameplate).

3. Make certain the reconnect

panel is configured properly for
the applied voltage.

1. Perform the Auxiliary

Transformer Test #1

2. Perform the Main Contactor

Test.

3. Perform the Reconnect

Switch Test #1.

4. Perform the Reconnect

Switch Test #2.

5. Perform the Input Rectifier

Test.

6. Perform the Switch Board

Test.

7. Perform the Snubber and

Bleeder Resistor Test.

8. The protection board may be

faulty. Replace.

9. The input filter capacitors may

be faulty. Replace.