beautypg.com

Troubleshooting & repair, Warning, Procedure – Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B User Manual

Page 244

background image

F-184

F-184

MAIN INPUT CONTACTOR (CR1) REMOVAL AND REPLACEMENT

(continued)

FIGURE F.69 - MAIN CONTACTOR

CR1

L

1A

L1

L2

L3

T1

T2 T3

324

326

T1

T3

L

3A

TROUBLESHOOTING & REPAIR

PROCEDURE

1. Remove main input supply power to the

machine.

2. With the 3/8" nut driver, remove the 4

screws that hold the handle to the machine.

3. Remove the rubber gasket (cover seal) from

the lift bail.

4. With the 5/16" nut driver, remove the sheet

metal screws from the case top.

5. With the 5/16" nut driver, remove the

screws holding the right and left case sides.
Remove the case sides by lifting up and
out.

6. Perform the Capacitor Discharge Proce-

dure described earlier in this section of the
manual.

Before continuing with the
test procedure, perform the
capacitor discharge proce-
dure to avoid electric shock.

7. After you have completed the capacitor dis-

charge procedure for all four switch boards,
with the slot head screw driver, remove the
three heavy leads from the output side of
the contactor.

8. With the slot head screw driver, remove the

two small leads (L1A and L3A) from the
input side of the contactor.

POWER WAVE 450