SNUBBER AND BLEEDER RESISTOR TEST

(continued)

TROUBLESHOOTING & REPAIR

C. With the volt/ohmmeter, check for 25

ohms resistance between lead #404 and
#9F.

If the measurement reads between 20 and
30 ohms, resistor R4 and leads #404 and
#9F are okay. Go to step D.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #404 and #9F. Then test for 25 ohms
resistance across R4 directly. If the mea-
surement does not read between 20 and
30 ohms, replace resistor R4.

D. Reconnect quick connect terminals #403,

#404, #9, and #12 on switch board 2.

Switch Board 3: (Switch Board 3 is Marked
CAP 1 on the Switch Board Assembly
Connection Decal - See Figure F.24.
)

A. Remove quick connect terminals #405,

#406, #9, and #12 from switch board 3.

B. With the volt/ohmmeter, check for 25

ohms resistance between lead #405 and
#12G.

If the measurement reads between 20 and
30 ohms, resistor R5 and leads #405 and
#12G are okay. Go to step C.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #405 and #12G. Then test for 25
ohms resistance across R5 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R5.

C. With the volt/ohmmeter, check for 25

ohms resistance between lead #406 and
#9G.

If the measurement reads between 20 and
30 ohms, resistor R6 and leads #406 and
#9G are okay. Go to step D.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #406 and #9G. Then test for 25
ohms resistance across R5 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R5.

D. With the volt/ohmmeter, check for 7.5 K-

ohms resistance between lead #12G (12M)
and #9G (9M).

If the measurement reads between 6.75
and 8.25 K-ohms, resistor R10 and leads
#12G (12M) and #9G (9M) are okay. Go to
step E.

If the measurement does not read between
6.75 and 30 K-ohms, check for continuity
in leads #12G (12M) and #9G (9M). Then
test for 7.5 K-ohms resistance across R10
directly. If the measurement does not read
between 6.75 and 8.25 K-ohms, replace
resistor R10.

E. Reconnect quick connect terminals #405,

#406, #9, and #12 on switch board 3.

Switch Board 4: (Switch Board 4 is Marked
CAP 4 on the Switch Board Assembly
Connection Label - See Figure F.24.
)

A. Remove quick connect terminals #407,

#408, #9, and #12 from switch board 4.

B. With the volt/ohmmeter, check for 25

ohms resistance between lead #407 and
#12H.

If the measurement reads between 20 and
30 ohms, resistor R7 and leads #407 and
#12H are okay. Go to step C.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #407 and #12H. Then test for 25
ohms resistance across R3 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R7.

C. With the volt/ohmmeter, check for 25

ohms resistance between lead #408 and
#9H.

If the measurement reads between 20 and
30 ohms, resistor R8 and leads #408 and
#9H are okay. Go to step D.

If the measurement does not read between
20 and 30 ohms, check for continuity in
leads #408 and #9H. Then test for 25
ohms resistance across R8 directly. If the
measurement does not read between 20
and 30 ohms, replace resistor R8.

D. Reconnect quick connect terminals #407,

#408, #9, and #12 on switch board 4.

8. Install the machine case sides and top.

9. Install the handle and the lift bail rubber

gasket.