6 stopping tests, Stopping tests 3–12 – Sun Microsystems Sun Fire V20z User Manual
Page 52
3-12
Sun Fire V20z Server User Guide • March 2004
The following is an example of two passed test cases and one failed test case:
3.4.6
Stopping Tests
To cancel one or more individual tests, run the following command:
# diags cancel tests [[{ -t | --test}
test_handle [{-a|--all}]
Where test_handle is a dynamically assigned unique number used by the diagnostics
application to identify a running test. The test handle is displayed in the output of a
test after it has been run.
To terminate all diagnostics tests and end the diagnostics session, run the following
command:
# diags terminate
Refer
to Appendix C for more information about these commands.
Results
Submitted Test Name Test Handle Test Result
adjacency.allDimms P1 Passed
dataline.allDimms P2 Passed
pattern.allDimms P3 Failed
Failure Details: FAILED, addr(0xc0000008) CPU 1 - DIMM 3)
Expected [5a5a5a5a5a5a5a5a] Actual [a5a5a5a5a4a5a5a5] Difference
[1000000]
Memory Configuration: Total: 3584Mb
CPU0-2048Mb CPU1-1536Mb
CPU 0: Width[128] Addr 0 - 7fffffff
DIMM 0 512MB Addr 0000000000 - 003fffffff Even Quad Word
DIMM 1 512MB Addr 0000000000 - 003fffffff Odd Quad Word
DIMM 2 512MB Addr 0040000000 - 007fffffff Even Quad Word
DIMM 3 512MB Addr 0040000000 - 007fffffff Odd Quad Word
CPU 1: Width[128] Addr 80000000 - dfffffff
DIMM 0 512MB Addr 0080000000 - 00bfffffff Even Quad Word
DIMM 1 512MB Addr 0080000000 - 00bfffffff Odd Quad Word
DIMM 2 256MB Addr 00c0000000 - 00dfffffff Even Quad Word
*DIMM 3 256MB Addr 00c0000000 - 00dfffffff Odd Quad Word