C.1 diags cancel tests, C.1.1 command, C.1.2 return codes – Sun Microsystems Sun Fire V20z User Manual
Page 100
C-2
Sun Fire V20z Server User Guide • March 2004
C.1
diags cancel tests
C.1.1
Command
Access: Administrators
Description: Cancels one or more diagnostic tests, resulting in the deletion of results
data.
Command format: diags cancel tests [[{ -t | --test} test_handle] [{-
a|--all}] [{-H | --noheader}]]
Specifying no arguments cancels all tests for each device in the system.
C.1.2
Return Codes
Following are the return values for this command:
Arguments
Description
{ -t | --test}
Specifies the test to cancel. (Note: The test_handle is
the same as the test handle that is output to the
screen when you submit the test.)
{-a | --all}
Cancels all tests.
{-H | --noheader}
Suppresses header output.
Return Code
ID
Description
NWSE_Success
0
Command successfully completed.
NWSE_InvalidUsage
1
Invalid usage: bad parameter usage,
conflicting options specified.
NWSE_RPCTimeout
2
Request was issued, but was not serviced
by the server. RPC procedure timed out
and the request may or may not have
been serviced by the server.