5 viewing test results, Viewing test results 3–11 – Sun Microsystems Sun Fire V20z User Manual
Page 51
Chapter 3
Troubleshooting and Diagnostics
3-11
To run the diagnostics tests, type the following command:
# diags run tests
option
Where the
option is one of the following:
For example, if
you suspect that you are having voltage problems, run the voltage
module diagnostic tests:
# diags run tests -m voltage
more information about using these command options.
You can write scripts for additional control over the sequencing and timing of the
tests. For example, you could write a shell script to repeat a test a specified number
of times.
3.4.5
Viewing Test Results
After a test successfully executes, the status returns. When a test receives an error, it
reports the error and continues to run any remaining tests submitted with the
command.
The following output is typically generated for all diagnostics tests:
■
Submitted Test Name
■
Test Handle (
a dynamically assigned unique number used by the diagnostics
application to identify a running test)
■
Test Result (Passed, Failed)
■
Details (for example, Failure Details, Tests Details)
Specifying the
-v | --verbose option when running the test displays additional data
about a test. See Appendix C for more details.
For example, test details may include high, nominal, and low values.
Option
Description
-n
test_name
To run one test at a time, replace
test_name with the name of the test. You
can specify more than one test by listing test names with a space between
them.
-m
module
To run a batch of tests by module, replace module with the name of
the test module.
-a
Use this option to run all available diagnostics tests.