C.1.3 diags get state, C.1.3.1 command, C.1.3.2 return codes – Sun Microsystems Sun Fire V20z User Manual
Page 101
Appendix C
Diagnostics Commands
C-3
C.1.3
diags get state
C.1.3.1
Command
Access: Administrators
Description: Returns the state of the platform diagnostics control server.
Command format: diags get state
If you get a success text message returned from the command, the platform is up
and ready for diagnostics and you can submit platform diagnostic tests for
execution.
If you get an error text message, the platform diagnostics are not up, and you will
need to wait to run the platform diagnostics tests.
C.1.3.2
Return Codes
Following are the return values for this command:
NWSE_RPCNotConnected
3
Unable to connect to the RPC server.
NWSE_InvalidArgument
4
One or more arguments were incorrect or
invalid.
NWSE_NoPermission
6
Not authorized to perform operation.
NWSE_MissingArgument
7
Missing argument(s).
Return Code
ID
Description
NWSE_Success
0
Command successfully completed.
NWSE_InvalidUsage
1
Invalid usage: bad parameter usage,
conflicting options specified.
NWSE_DeviceError
25
Unable to read or write to the device.
Return Code
ID
Description