14.2 Parameters

The following sections describe the configurable parameters in the

lanman.ini

file. The

parameters are grouped according to the section of the

lanman.ini

file in which they reside.

The lanman.ini file contains additional parameters that are not included in the

following tables. These parameters are for debugging purposes and should never
be modified.

[server] Section Parameters

Parameter

Description, Values, and Default Setting

listenname

This is the server’s name on the network.
To change the value of the listenname parameter, use
the setservername command. For more information
about this command, type man setservername at the
Advanced Server command prompt.
Values: any servername of 1-15 characters
default: null

maxclients

Identifies the maximum number of simultaneous client
sessions that the server must support. This number is
set by default to 250. It can be increased to a number
that is equal to the Advanced Server user licence.

ProductType

Specifies the type of installed Advanced Server for
UNIX. Possible values are ServerNT and LanmanNT.
This parameter is set to the correct value automatically
when Advanced Server for UNIX is configured and
must not be changed.
Default: LanmanNT

srvservices

The list of keywords for the services that start automat-
ically when the server is started. Because services are
started in the order they appear in the srvservices entry,
you must ensure that

netlogon

appears before any

services that require it.
Default: alerter, netlogon, browser