Bit-Mapped Options Status (Indicates the status of command
Options.) LAPM Failure Control Default: 7
Bits 0-2 This option indicates what should happen upon a LAPM failure.
These fallback options are initiated immediately upon connection if S48 =
128. If an invalid number is entered, the number is accepted into the
register, but S36 will act as it the default value has been entered.
0 = Modem Disconnects.
1 = Modem stays on-line and a Direct mode
connection is established.
2 = Reserved
3 = Modem stays on-line and a Normal
mode connection is established.
4 = An MNP connection is attempted and if
it fails, the modem disconnects
5 = An MNP connection is attempted and if
it fails, a Direct mode connection
is established
6 = Reserved
7 = An MNP connection is attempted and if
it fails, a Normal modem connection
is established (Default)
Bits 3-7
Reserved
S37
Bit-Mapped Options Status (Indicates the status of command
Options.) Desired DTE Connection Speed Default: 0
When the Nn command is issued or the S37 register value is modified, the
+MS command subparameters are updated to reflect the speed and the
modulation specified bit the S37 value. For Example:
If N0 command is active, S37 = 10 updates the +MS command subparam-
eters to reflect +MS = 10,1,300,12000.
IF N1 command is active, S37 = 10 updates the +MS command subparam-
eters to reflect +MS = 10,0,12000,12000.
S37 is not updated by the +MS command.
Use of the +MS command is recommended instead of the Nn and S37 = x
commands. Nn and S37 = x commands are supported for compatibility with