Command: Zn
Modem Reset
Values:
n = 0 or 1
Default:
None
Description: Z0
Reset modem to profile saved by the last &W
command (profile 0).
Z1
Reset and restore stored profile 1.
Command: &Cn Data Carrier Detect (DCD) Control
Values:
n = 0 or 1
Default:
1
Description: &C0
Ignores the state of carrier on the remote modem and
DCD circuit is always on.
&C1
DCD turns on when the remote modems carrier
signal is detected and DCD is off when the carrier
signal is not detected.
Command: &Dn Data Terminal Ready (DTR) Control
Values:
n = 0, 1, 2, or 3
Default:
2
Description: &D0
Modem ignores the true status of the DTR signal and
responds as if it is always on.
&D1
When DTR drops while in online data mode, the
modem enters command mode, issues an OK, and
remains connected.
&D2
When DTR drops while in online data mode, the
modem hangs up (Auto-Answer is encumbered).
&D3
When DTR drops, the modem hangs up and resets as
if an ATZ command were issued.
Command: &Fn
Load Factory Default Settings
Values:
n = 0 or 1
Default:
None
Description: &F0
Restore factory configuration 0.
&F1
Restore factory configuration 1.
Command: &Gn V.22bis Guard Tone Control
Values:
n = 0, 1, or 2
Default:
0
Description: &G0
Disable guard tone.
&G1
Enable 550 Hz guard tone.
&G2
Enable 1800 Hz guard tone.