Model MT5600ZDX

S16

General Bit Mapped Test Options Status. Indicates the Test in

progress status: Default 0.

Bit 0

Local Analog Loopback

0 = Disabled (Default)

1 = Enabled (&T1)

Bit 1

Not Used

Bit 2

Local Digital Loopback

0 = Disabled (Default)

1 = Enabled (&T3)

Bit 3

Remote Digital Loopback (RDL) status

0 = Modem not in RDL (Default)

1 = RDL in progress

Bit 4

RDL Requested (AT&T6)

0 = RDL not requested (Default)

1 =RDL requested (&T6)

Bit 5

RDL with self test

0 = Disabled (Default)

1 =Enabled (&T7)

Bit 7

Not used

S18

decimal 0–255

0

Sets the length of time, in sec-

onds, that the modem conducts a

test (commanded by &Tn) before

returning to the command mode.

If this register value is zero, the

test will not automatically termi-

nate; the test must be terminated

from the command mode by issu-

ing and &T0 or H command.

When S18 is non-zero, the mo-

dem returns the OK message upon

test termination.