Multi-Tech Systems MT5600ZDX User Manual
Page 32

32
Model MT5600ZDX
Command: &Jn
Telephone Jack Control
Values:
n = 0 or 1
Default:
None
Description: &J0
NA
&J1
NA
*This command is only included for compatibility and performs no
function except to load the S-Register. The parameter value, if valid, is
written S21 bit 1.
Command: &Kn Flow Control Selection
Values:
n = 0, 3, 4, 5 or 6
Defaults:
3
Description: &K0
Flow control disabled.
&K3
Enable CTS/RTS hardware flow control.
&K4
Enable XON/XOFF flow control.
&K5
Enable transparent XON/XOFF flow control.
&K6
Enable both RTS/CTS and XON/XOFF flow control.
(Default for fax and voice modes.)
Command: &Ln
Leased Line Operation
Values:
n = 0
Defaults:
None
Description: &L0
NA
*This command requests leased line or dial-up operation. This command
is provided for compatibility only; no mode change is performed, dial-up
operation continues. The OK response is returned for a valid parameter, but
no other action is performed. The parameter value, if valid, is written to
S27 bit 2.
Command: &Mn Communications Mode
Values:
n = 0
Defaults:
0
Description: &M0
Asynchronous mode.
&M1
Reservedresponds ERROR.
*&M0 selects direct asynchronous operation. Note that the command
sequence &M0\N0 selects normal buffered mode, but the command
sequence \N0&M0 selects direct mode. This is because the \N0 command
is analogous to the &Q6 command.