beautypg.com

Multi-Tech Systems MT5600ZDX User Manual

Page 33

background image

33

Owner’s Manual

Command: &Qn Asynchronous Communications Mode

Values:

n = 0, 5, or 6

Defaults:

5

Description: &Q0

Asynchronous with no data buffering/no error

correction. Same as \N0.

&Q5

Asynchronous with data buffering/error correction.

Same as \N3.

&Q6

Asynchronous with data buffering/no error correc-

tion. Same as \N0.

Command: &Sn Data Set Ready (DSR) Control

Values:

n = 0 or 1

Default:

0

Description: &S0

Force DSR ON at all times.

&S1

DSR becomes active after answer tone is detected

(CD), and inactive after carrier tone is lost.

Command: &Tn

Test Commands

Values:

n = 0, 1, 3, 4, 5, 6, 7 or 8

Default:

None

Description: &T0

Abort. Stop any test in progress.

&T1

Starts Local Analog loop test.

&T2

Returns Error.

&T3

Starts Local Digital loopback test.

&T4

Responds to remote modem request for Digital Loop-

back.

&T5

Ignores remote modem request for Digital Loopback.

&T6

Requests remote Digital Loopback without self-test.

&T7

Requests remote Digital Loopback with self-test.

&T8

Starts Local Analog loop test with self-test.