The modem dials but cannot make a connection – Multi-Tech Systems MT5634ZPX User Manual

Page 56

background image

MT5634ZPX

56

Owner’s Manual

The Modem Dials But Cannot Make a
Connection

There can be several reasons the MultiModemZPX fails to make
a connection. Possibilities include

lack of a physical connection to the telephone line.
a wrong dial tone.
a busy signal.
a wrong number.
no modem at the other end.
a faulty modem, computer, or software at the other end.
incompatibility between modems.

You can narrow the list of possibilities by using extended result
codes. If you have disabled the modem’s extended result codes,
re-enable them by entering ATV1X4 in the terminal window and
pressing ENTER. When you dial again, the modem will report
the call’s progress.

If the modem reports

NO DIALTONE

, check that the

modem’s telephone line cable is connected to both the
modem’s LINE jack (not the PHONE jack) and the telephone
wall jack. If the cable looks secure, try replacing it. If that
doesn’t work, the problem may be in your building’s
telephone installation. To test the building installation, plug a
telephone into your modem’s telephone wall jack and listen
for a dial tone. If you hear a dial tone, your modem may be
installed behind a company phone system (PBX) with an
internal dial tone that sounds different from the normal dial
tone. In that case, the modem may not recognize the dial
tone and may treat it as an error. Check your PBX manual to
see if you can change the internal dial tone; if you can’t,
change your modem’s initialization string to include

X3

,

which will cause the modem to ignore dial tones. (Note,
however, that

X3

is not allowed in some countries, such as

France and Spain.)