beautypg.com

S-registers – Multi-Tech Systems MT5634ZPX User Manual

Page 46

background image

MT5634ZPX

46

Owner’s Manual

S-Registers

S-registers generally affect how the AT commands perform. You
can read or alter the contents of an S-register by using the S
command (see “AT Commands”).

Register Unit

Range

Default

Description

S0

rings

0, 1–255 1

Sets the number of rings before
the modem answers.

ATS0=0

disables auto-answer completely.

S1

rings

0–255

0

Counts the number of rings that

have occurred.

S2

decimal

0–127

43 (+)

Sets ASCII code for the escape

128–255

character. Values greater than

127 disable the escape sequence.

S3

decimal

0–127

13 (^M) Sets ASCII code for the carriage

return character.

S4

decimal

0–127

10 (^J)

Sets ASCII code for the line feed

character.

S5

decimal

0–32

8 (^H)

Sets ASCII code for the backspace

33–127

character. Values greater than 32

disable the backspace character.

S6

seconds 2–65*

2*

Sets the time the modem will wait

after it goes off-hook before it be-
gins to dial the telephone number.

S7

seconds 1–255*

50*

Sets the time the modem will wait
for a carrier signal before aborting
a call. Also sets the wait for si-
lence time for the @ dial modifier.

S8

seconds 0–65

2

Sets the length of a pause caused
by a comma character in a dialing
command.

S10

100 ms

1–254

20

Sets how long a carrier signal
must be lost before the modem
disconnects.

* These values may be different outside North America.