beautypg.com

Settrap, Setwritecommunity, Sync – Multi-Tech Systems MR9600 User Manual

Page 65: T, time

background image

5 Commands

CommPlete Communications Server

57

settrap

Parameter:

IP Address

Description:

Changes the default trap IP address to the one specified in the parameter. This IP address is

where fault and status traps are sent. See se.

Security:

Supervisor

Limitations:

Only one default trap address may be set at a time.

Example:

[0] A:\ # settrap 199.199.199.6
Trap IP Address 199.199.199.6 stored
[1] A:\ #

setwritecommunity

Parameter:

None

Description:

Changes the Write community settings.

Security:

Supervisor

Example:

[0] A:\ # setwritecommunity public
Write Community public stored
[1] A:\ #

sync

Parameter:

None

Description:

Writes oustanding events (events that normally get written every hour) to the

B:\#MMM\MR.log directory. The file will be named the current date and hour with an hour extension.

Security:

Operator

Example:

[01] A:\ # sync
[02] A:\ #

t, time

Parameter:

None

Description:

Prompts you to change the time on the MR9600.

Security:

Operator

Limitations:

The time is not corrected for daylight savings time.

Example:

[0] A:\MMM # t
The current time is: 4:59pm
Enter the new time: hh:mm 17:10

[1] A:\MMM # cl
10/30/1996 5:10pm

[2] A:\MMM # t
The current time is: 5:10pm
Enter the new time: hh:mm 5:12pm

[3] A:\MMM # cl