beautypg.com

Pristatus, Quit, Rassetup – Multi-Tech Systems MR9600 User Manual

Page 58

background image

MR9600 User Guide

50

CommPlete Communications Server

Security:

Operator

Example:

[1] A:\MMM # prisetup 10a

Use settings from:

1. Use Active Settings (pre-configured card)
2. Use System Defaults (new card)
3. Use Stored Settings (swapping cards)

Enter Selection (q(uit), <1>): 1
Getting PRI Info .....

1. Switch Type :AT&T 5ESS
2. Line Coding :Binary 8 Zero Substitution (B8ZS)
3. Framing Format :Extended Super Frame
4. Error Correction (CRC4/6):Enabled
5. Call Distribution :One to One
6. Set Carrier :PCM24/T1
7. Active Channels :23

Enter Selection (-(previous), q(uit), d(one), <1>):

pristatus

Parameter: Drive Specifier

Description:

Retrieve the current status of the specified PRI card

Security:

Operator

Example:

[2] A:\MMM # pristatus 10a

Getting PRI Info ....

Switch Type:AT&T 5ESS
Line Coding:Binary 8 Zero Substitution (B8ZS)

Framing Format:Extended Super Frame

Error Correction (CRC4/6):Enabled

Call Distribution:One to One

Set Carrier:PCM24/T1

Active Channels:23

Model:MTPRI-HD23B

Version:2.57E.44 / 232

Layer 1 Status:Up
Layer 2 Status:Multi-Frame Established

Number of Channels:23

quit

Parameter:

None

Description:

Logs the User off of the system.

Security:

Guest

Example:

[05] A:\ # quit
Bye.
Username:

rassetup

Parameter:

Device

Description:

Sets the RASExpress configuration associated with a RAS Card. The device specified must be

a RAS card device.