CHAPTER 4: Installing Components
www.gateway.com
50
5
Disconnect the main power, CPU power, backplane power, I
2
C power, and
midplane power cables. See
the connectors on the system board.
6
Loosen the thumbscrew (1) holding the power distribution board in place,
then slide the power distribution board (2) away from the side of the
chassis to release it.
7
Lift the power distribution board (3) out of the chassis.
Important
Make sure that the power supply cable
box is connected to the power supply
connector(s) on the power supply(ies).
8
Align the new power distribution board with the power supply cage and
the standoffs, then push it down onto the standoffs.
9
Slide the power distribution board toward the side of the chassis, then
tighten the thumbscrew to secure it to the chassis.
10
Reconnect the power cables. See
for the
location of the connectors on the system board.
11
Set the case upright, if required.
12
Reinstall the power supply modules by following the instructions in
“Replacing a power supply module and power board” on page 48
13
Follow the instructions in
“Closing the server case” on page 30
.