L15-30 plug (as recommended), Angle sensor digital readout fuse, Power junction box – Grizzly G0696X User Manual
Page 2: Angle sensor digital readout, On/off switch magnetic switch assembly mpe-30, Motor 440v 3-ph, Phase converter, Parts changes, 220 vac

Copyright © NoVEMBEr, 2011 By grizzly iNdustrial, iNC.
Warning: no portion of this manual may be reproduced in any shape
or form Without the Written approval of grizzly industrial, inc.
#KN14523 priNtEd iN taiWaN
We recently made the following changes to this machine and its manual:
•
Changed the motor from a 9-wire to a 12-wire version.
•
updated the wiring diagram for the new motor.
aside from the information contained in this update, all other content in the owner's manual applies to this
machine. For your own safety, you Must read and understand this update and the applicable owner's
manual.
Keep this update for future reference!
If you have any further questions about this manual update or the changes made to the machine, contact
our Technical Support at (570) 546-9663 or email [email protected].
model g0606X1/g0697X
***IMPORTANT UPDATE***
applies to models mfg. since 9/11
and owner's manual July, 2010
revised motor 220v 3-phase Wiring
revised motor 440v 3-phase Wiring
R/1/L1
T/5/L3
NO13
S/3/L2
NC15
U/2/T1
W/6/T3
220V
V/4/T2
NC16
NO14
95
A
SDE
MA-30
Ground
1/2
3/4
5/6
11
22
RESET
OFF
SDE RA-30
96
98
B
440V
Ground
Hot
Hot
Hot
L15-30 PLUG
(as recommended)
220 VAC
OFF
ON
14
24
23
13
Angle Sensor
Digital Readout
Fuse
AC2
R18
AC1
On/Off Switch
Magnetic
Switch
Assembly
MPE-30
Motor 220V 3-Ph
If connecting machine to a phase
converter, the manufactured leg
must be connected to terminal L3.
PHASE CONVERTER
Power Junction Box
Installation work and electrical wiring
must be done by qualified electrician in
accordance with all applicable codes
and standards.
Ground
V2
U2
W2
W5
W1
V6
U6
W6
U5
V1
V5
U1
220V
R/1/L1
T/5/L3
NO13
S/3/L2
NC15
U/2/T1
W/6/T3
220V
V/4/T2
NC16
NO14
A
SDE
MA-30
Ground
RESET
96
98
1/2
3/4
5/6
11
22
OFF
95
SDE RA-30
B
220V
OFF
ON
14
24
23
13
Angle Sensor
Digital Readout
AC2
R18
AC1
On/Off Switch
Magnetic
Switch
Assembly
MPE-30
Ground
Hot
Hot
Hot
DISCONNECT
SWITCH
(as recommended)
3-PHASE
440 VAC
Power Junction Box
Installation work and electrical wiring
must be done by qualified electrician in
accordance with all applicable codes
and standards.
440V
Motor 440V 3-Ph
Ground
V2 U2
W2
V6
W1
V1
U6
U1
W6
V5
U5
W5
parts changes
REF PART #
DESCRIPTION
6V2
P0606X1006V2
MOTOR 7-1/2 HP 220V/440V 3-PH V2.11.11
6V2-1 P0606X1006V2-1 MOTOR FAN COVER
6V2-2 P0606X1006V2-2 MOTOR FAN
6V2-3 P0606X1006V2-3 WIRING JUNCTION BOX
6V2
6V2-2
6V2-1
6V2-3