Voltage conversion, Notice – Grizzly G0696X User Manual
Page 16
g0605X1-6X1, g0696X-97X (mfg. 8/11+)
-13-
voltage conversion
Ground
V1
U1
Z1
Y1
X1
V2
U2
W1 W2
Figure 7. motor rewired to 440v.
5. remove the magnetic switch cover and move
the fuse on the fuse block from the 220v
slot to the 440v slot, as shown in
Figure 8.
(Additionanally, refer to the photos on
page
80 and wiring diagram on page 82 for futher
details.
440V
220V
Figure 8. Fuse moved from 220v to 440v slot.
440v Fuse
location
relay dial
7. re-install the magnetic switch cover and
close and secure the motor cover.
6. turn the thermal overload relay dial from 22
amps to 11 amps, as shown in
Figure 9.
RESET
96
98
3/4
5/6
11
22
OFF
W/6/T3
V/4/T2
NO14
95
SDE RA-30
B
Figure 9. overload relay dial turned to 11 amp
setting.
4. rewire the motor, as shown in Figure 7,
tighten the hex nuts, then re-install the junc-
tion box cover.
the model g0606X1/g0697X can be converted
for 440v operation.
this conversion job consists of disconnecting the
saw from the power source, rewiring the motor,
switching the transformer fuse from 220v to 440v,
and changing the thermal overload relay from 22
to 11 Amps.
NOTICE
Refer to the motor junction box cover dia-
gram for motor connection locations and
voltage conversion. If not present, use the
instructions below, or call our Tech Support
Department at (570) 546-9663.
converting Model G0606X1/G0697X
to 440v
1. disConnECt sAW From poWEr!
2. open the motor cover, remove the motor
junction box cover, then loosen the hex nuts
shown in
Figure 6.
3. remove the two jumpers (they are stacked
together), as indicated in
Figure 6.
Ground
Z1 Y1 X1
W1
W2
V1
V2
U1
U2
Figure 6. motor rewired to 440v.
loosen
these hex
nuts
Jumpers