Installation in 3rd party racks – FUJITSU Server TX200 S6 User Manual

Page 57

background image

TX200 S6

Operating Manual

57

Hardware installation

V

CAUTION!

Ensure that the safety lock has been inserted before the server is
inserted (see

figure 5 on page 54

).

V

CAUTION!

At least two people are needed to position the server in the rack.
(For the Japanese market, please refer to "

安全上の注意およびその他の

重要情報

".)

Ê

Extend the telescopic rails completely to the front (1).

I

They must click into place so that they can no longer be moved.

Ê

Lower the server from above onto the projecting telescopic rails (2), (3). As
you do this, the locking bar (4) engages.

Ê

Push the locking mechanism of both telescopic rails up (5).

Ê

For a final function test, slide the server in and out at least twice.The rails
should move smoothly.

Ê

Push the server as far as it will go into the rack (6).

Ê

Fasten the server to the rack (7) using the two knurled screws (front panel).

Ê

Route the cables as described in the technical manual for the rack in
question with the server pushed in.

4.3.3

Installation in 3rd party racks

I

The support systems from Fujitsu are suitable for use in any 3rd party
racks for standard servers (installation depth 714 - 785 mm) without
restrictions.

Ê

Refer to the manual from the rack manufacturer for details of the mechanical
installation and the climatic conditions.

V

CAUTION!

When installing in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.

Ê

Fit the required original parts (support bracket or cable management
system).