Setting up the floorstand model, 2 setting up the floorstand model – FUJITSU Server TX200 S6 User Manual
Page 47

TX200 S6
Operating Manual
47
Hardware installation
4.2
Setting up the floorstand model
I
If you are not installing a PRIMERGY TX200 S6 floorstand model, skip
this section and continue reading at
section "Installing/removing the rack
.
V
CAUTION!
Follow the safety instructions in
chapter "Important information" on
.
Ê
Transport the server to the place where you want to set it up.
Ê
Unpack the server (see
section "Unpacking the server" on page 46
).
Ê
Set up the server.
Note that for safety reasons (danger of tipping) the anti-tilt bracket must be
mounted on the back of the server (see section
).
V
CAUTION!
–
The device must be protected from direct sunlight.
–
The essential minimum clearance for servicing must be
maintained (see
"Maintenance area for the floorstand model" on
–
Access to the rear of the server must be assured so that other
devices (e.g. memory subsystems) can be connected.
–
A clearance of at least 200 mm must be maintained in front of and
behind the system to ensure proper ventilation.
–
The mains plug must be accessible easily and safely.
Ê
Wire the server. Read the information in
section "Connecting devices to the
section "Notes on connecting/disconnecting cables"
.
Ê
Connect the system to the mains (see
section "Connecting the server to the
).