TX200 S6

Operating Manual

55

Hardware installation

I

The support system no longer has to be fixed to the front support
upright because the easy lock engages and ensures a firm fit.

Ê

Insert (3) the safety lock into the easy lock (snap fit).

V

CAUTION!

Ensure that the safety lock has been inserted before the server is
inserted!

Ê

Repeat the above steps for the right-hand support system (with the front and
rear right support uprights).

Ê

Fit the PRIMECENTER/DataCenter rack cable management as described in
the technical manual for the corresponding rack.

Figure 6: Position of the cage nuts

Ê

Fit the cage nuts for securing the server in the corresponding catches on the
right and left support uprights.

Ê

Insert the server (see

"Inserting the server" on page 56

).

1

5

10

15

14

14