1.5

Technical data

Electrical data

Compliance with regulations and standards

Rated voltage range

100 V - 240 V

Frequency

47 Hz - 63 Hz

Rated current with basic configuration 100 V oder 240 V / 1.3 A - 0.6 A

Max. rated current

100 V - 127 V oder 200 V - 240 V /
9.5 A - 4.0 A

Effective power

max. 461 W

Apparent power

max. 490 VA

Heat dissipation

1659.6 kJ/h (1573 BTU)

Main power fuse

16 A

Protection class

I

Product safety and
ergonomics

IEC 60950-1 / EN 60950-1, UL/CSA 60950-1,
CNS 14336 / GB 4943 / EN 50371

Electromagnetic
compatibility

FCC class A
CNS 13438 class A; VCCI class A
AS/NZS CISPR 22 class A / GB 9254 class A
GB 17625

interference emissions EN 55022 class A

Harmonic current

EN 61000-3-2

Flicker

EN 61000-3-3

interference immunity

EN 55024, EN 300386

CE marking
to EU directives

Low Voltage Directive 2006/95/EC
(product safety)
Electromagnetic compatibility 2004/108/EC

Mechanical environmental
conditions

EN 60721-3-3; class 3M2