To enter SPL Display Calibration mode:

1

Enter SETUP mode. The SETUP LED lights

green.

2

Turn the MONITOR encoder until the display

shows “SPLCAL.”

3

Press the MONITOR encoder button to select

SPLCAL. The SETUP LED blinks on and off.

4

Turn MONITOR encoder until the display

shows one of the following options:

• CalMn (calibrate SPL for MAIN)

– or –

• CalAlt (calibrate SPL for ALT)

5

Press the MONITOR encoder button to select

the displayed option.

6

For the selected Monitor Path option (MAIN

or ALT), turn the MONITOR encoder until the
display shows SET.

7

Press the MONITOR encoder button to select

the SET. The display changes to show 85SPL.

8

Turn the MONITOR encoder to until the SPL

reading is displayed.

9

Press the MONITOR encoder button to con-

firm the setting.

10

Press SETUP button to exit SPLCAL and re-

turn to top level of SETUP Options menu. The
SETUP LED stops blinking and lights solid green.

11

Exit SETUP mode.

To cancel the SPL value:

1

Enter SETUP mode. The SETUP LED lights

green.

2

Turn the MONITOR encoder until the display

shows “SPLCAL.”

3

Press the MONITOR encoder button to select

SPLCAL. The SETUP LED blinks on and off.

4

Turn MONITOR encoder until the display

shows one of the following options:

• CalMn (calibrate SPL for MAIN)

– or –

• CalAlt (calibrate SPL for ALT)

5

Press the MONITOR encoder button to select

the displayed option.

6

For the selected Monitor Path option (MAIN

or ALT), turn the MONITOR encoder until the
display shows NO SPL.

7

Press the MONITOR encoder button to con-

firm the setting.

8

Press SETUP button to exit SPLCAL and return

to top level of SETUP Options menu. The SETUP
LED stops blinking and lights solid green.

9

Exit SETUP mode.