Error codes, Hot error – unit is overheated – Hensel Expert D 250 SPEED Monolight User Manual
Page 86
User Manual Expert D 250 Speed / D 500 / D 1000
86
HENSEL-VISIT GmbH & Co. KG
Error Codes
Display
In case of an error, an error code
is shown in display. In this case
proceed as follows:
Switch off the unit.
Wait a few seconds.
Switch the unit on again.
If the error code persists, check if the problem can be remedied according
to the following list or contact customer service and state the error code,
see paragraph „Customer service points“.
Hot Error – Unit is Overheated
In case of this problem, the
modeling light shuts off, the fan
blows at full speed and the unit
stops flashing.
Keep the unit switched on so
that the fan continues to cool
the flash unit.
Possible causes can be extensive
flashing, high ambient
temperatures with full modeling
light, covered core ducts,
unsuitable reflectors or a defective
fan.