PM Mode (in connection with Power Max L)
Hallmarks of the compact flash units of the Expert D series are their
especially short flash duration times and fast recycling times - also when
operated with a Power Max L. This results in a comparatively high power
draw. In order to guarantee optimum functioning, the Expert D must be
switched to a special mode when used in connection with a Power Max L.
In this mode, the modeling light is set to 100W and the „Flash Check“
function, which turns off the modeling light after flashing and turns it back
on as soon as the unit has recharged and is ready to flash again, is
activated.
Activate PM Mode
Mains socket
Connect the compact flash
unit to one of the power
jacks on the Power Max L.
Power switch
Switch the Power Max L on
via the power switch.
Key SLAVE
Power switch
Switch the compact flash unit
via the power switch.
Press the key SLAVE until you
hear a beep tone.