Performance Output Adjustment
The rotary switch adjusts the flash output over an output range of 9 f-stops
(Expert D 250 Speed), from 2.0 (lowest output), and over an output range
of 8 f-stops (Expert D 500 / D 1000), from 3.0 (lowest output) to 10
(maximum output):
Flash readiness indicator
Rotary switch
The rotary switch adjusts the
flash output in steps of 0.1 f-.
Turning it counter-clockwise
reduces the output in steps of
0.1 f-stops.
The power dump takes a
moment. The flash readiness
indicator lights up to indicate
restored flash readiness.
When the performance output is reduced, the stored energy is reduced via
the internal APD-Function