Performance Output Adjustment

The rotary switch adjusts the flash output over an output range of 9 f-stops
(Expert D 250 Speed), from 2.0 (lowest output), and over an output range
of 8 f-stops (Expert D 500 / D 1000), from 3.0 (lowest output) to 10
(maximum output):

Flash readiness indicator

Rotary switch

The rotary switch adjusts the

flash output in steps of 0.1 f-.

Turning it counter-clockwise

reduces the output in steps of

0.1 f-stops.

The power dump takes a

moment. The flash readiness

indicator lights up to indicate

restored flash readiness.

When the performance output is reduced, the stored energy is reduced via
the internal APD-Function

3

.

3

APD: Automatic Power Drop