beautypg.com

Operator’s manual – Great Plains DICKEY-john Seed Manager SE Operator Manual User Manual

Page 60

background image

OPERATOR’S MANUAL

Seed Manager SE

11001-1359A-200810

58 / ALARMS

SHAFT SPEED LO LIMIT WARNING

Shaft Speed Lo Limit Warning occurs when any shaft speed falls below the
value entered for Shaft Speed Lo Limit in the SETUP MODE. The alarm
beeps for three (3) seconds and the shaft speed sensor number and actual
shaft speed, in RPM, display. If multiple shaft speed sensors fall below the
limit, the shaft speed sensor numbers display sequentially, along with their
respective shaft speeds. (

Figure 71

) shows a Shaft Speed Lo Limit Warning

on shaft speed sensor three (3) with a shaft speed of 427 RPM.

Figure 71
Shaft Speed Lo Limit Warning Display

PRESSURE HI LIMIT WARNING

Pressure Hi Limit Warning occurs when any pressure input exceeds the
value entered for Pressure Hi Limit in the SETUP MODE. The alarm beeps
for three (3) seconds and the pressure sensor number and actual pressure,
in oz/in

2

(kPa), display. If multiple pressure sensors exceed the limit, the

pressure sensor numbers display sequentially along with their respective
pressures. (

Figure 72

) shows a Pressure Hi Limit Warning on pressure

sensor one (1) with a pressure of 18.2 oz/in

2

.

Figure 72
Pressure Hi Limit Warning Display

PRESSURE LO LIMIT WARNING

This occurs when any pressure input falls below the value entered for
Pressure Lo Limit in the SETUP MODE. The alarm beeps for three (3)
seconds and the pressure sensor number and actual pressure, in oz/in

2

(kPa), display. If multiple pressure sensors fall below the limit, the pressure
sensor numbers display sequentially, along with their respective pressures.