Figure 63
Distance Accumulator Display

SPEED AREA MODE

Speed Area Mode monitors non-seeding operations, such as cultivating.
Only the Speed, Fan Speed, Shaft Speed, Pressure, Area, and Distance
Accumulator functions are available in this mode. (

Figure 51

) shows this

function availability in chart form. The console display for these functions is
identical in the Speed Area and Operate Modes.

To Enter Speed Area Mode:

1. A lift switch (implement status switch) must be connected to a shaft

speed module that is connected to the system and no seed sensors
can be connected.

2. Power off the console.
3. Wait a minimum of 10 seconds before re-powering the system.
4. Power on the console.
5. The alarm will sound momentarily and an E00 (No seed sensors

connected) error code will display. Press the OPERATE 2 or
OPERATE 3 switch depending on which Speed Area Mode function is
desired.

To accumulate area in the Speed Area Mode, the lift switch must indicate
the implement is down. Run Hours accumulate only when the implement is
down. The Distance Accumulator function is independent of the lift switch
status.