Operator’s manual – Great Plains DICKEY-john Seed Manager SE Operator Manual User Manual
Page 40

OPERATOR’S MANUAL
Seed Manager SE
11001-1359A-200810
38 / STARTUP
16. NUMBER OF PRESSURE SENSORS
This is the actual number of pressure sensors that are connected to a shaft
speed module on the system. This parameter will be checked as part of the
Sensor/Module Self-Test and error codes will be generated if this value
does not match the actual number of pressure sensors. (
Figure 40
) shows
a configuration of one (1) pressure sensor.
Figure 40
Pressure Sensor Display
16A and 16C. Pressure Sensor Hi Limit
The Pressure Sensor Hi Limit Warning is entered in oz/in
2
(kPa). The hi
and lo warning limits are accessible only if the Number of Pressure Sensors
has a value other than 0. Setting the Pressure Sensor Hi Limit will cause
the audible alarm to sound when the pressure exceeds the value that has
been entered. Use the SET and SELECT switches to adjust the Pressure
Sensor Hi Limit value. The Pressure Sensor Hi Limit can be enabled or
disabled by selecting the ON or OFF symbol after the rightmost digit.
Pressing the SET switch will toggle the status of the warning between ON
and OFF. (
Figure 41
) shows a Pressure Sensor Hi Limit of 18.0 with the
warning enabled.
Figure 41
Hi Limit Pressure Display