beautypg.com

Operator’s manual – Great Plains DICKEY-john Seed Manager SE Operator Manual User Manual

Page 59

background image

OPERATOR’S MANUAL

Seed Manager SE

11001-1359A-200810

ALARMS / 57

FAN SPEED LO LIMIT WARNING

Fan Speed Lo Limit Warning occurs when any fan speed falls below the
value entered for Fan Speed Lo Limit in the SETUP MODE. The alarm
beeps for three (3) seconds and the fan speed sensor number and actual
fan speed, in RPM, display. If multiple fan speed sensors fall below the
limit, the fan speed sensor numbers display sequentially, along with their
respective fan speeds. (

Figure 69

) shows a Fan Speed Lo Limit Warning

on fan speed sensor two (2) with a fan speed of 167 RPM.

Figure 69
Fan Speed Lo Limit Warning Display

SHAFT SPEED HI LIMIT WARNING

Shaft Speed Hi Limit Warning occurs when any shaft speed exceeds the
value entered for Shaft Speed Hi Limit in the SETUP MODE. The alarm
beeps for three (3) seconds and the shaft speed sensor number and actual
shaft speed, in RPM, display. If multiple shaft speed sensors exceed the
limit, the shaft speed sensor numbers display sequentially, along with their
respective shaft speeds. (

Figure 70

) shows a Shaft Speed Hi Limit Warning

on shaft speed sensor one (1) with a shaft speed of 1,592 RPM.

Figure 70
Shaft Speed Hi Limit Warning Display