7.12

tORQUE CALIBRATion

The function of this screen is to adjust the calibration (Cal) value of the FEC INC. torque
transducer with a master torque sensor.

7.12.1 Table of Contents

7.12.1. TAble of Contents for TORQUE Calibration screens
7.12.2. SCreen Explanation
7.12.3. SCReen OPERATION/PRINT FUNCTION

7.12.2 SCREEN EXPLANATION

2-1.

The TORQUE CALIbration screen is made up of two columns capable of listing 12
tools in each column. THe list automatically displays the tools that are connected to
the Axis Controller Units.

2-2.

EACh list contains the following:

SPD NO.

TOOl spindle number setup by the AXIS Unit dip switch setting


TOOL

TOol full scale torque calibration value from the EEPROM located in

FULL SCALE

the preamp connector housing


RATIO [%] THe preset ratio percentage between the FEC torque transducer and

the master torque transducer used to verify the calibration

FIG. 7-12-2 torque calibration screen