FEC AFC1200 User Manual
Page 18

)(& ,QF
(standard operating method)
YIELD METHOD
(CW/CCW)
Yield Control method
SPEED CHANGE TORQUE
Shiftpoint from 1st Step to torque speed
THRESHOLD 1 TORQUE
Start of 1st TORQUE RAte measurement
THRESHOLD 2 TORQUE
STart of FINAL ANGLE measurement
1ST TORQUE
SEat torque (1st Torque), end of 1st TORQUE RAte
measurement, start of 2nd TORQUE Rate measurement
CROSSOVER RATE 2
END of 2nd TORQUE Rate measurement, start of 3rd torque
TORQUE
Rate measurement
2ND TORQUE
TORque for 2nd Step in multi-step fastening
3RD TORQUE
TORque for 3rd Step in multi-step fastening
STD TORQUE
FINal target torque in TORQUE Control mode, end of 3rd
TORQUE RAte measurement
HIGH TORQUE
HIgh torque limit
LOW TORQUE
LOw torque limit
HIGH ANGLE
HIGh final angle limit
LOW ANGLE
LOw final angle limit
INCREMENT ANGLE
Preset angle for INTEGRATED TORQUE Rate
1ST TORQUE RATE HIGH
High limit for 1st TORQUE RAte
1ST TORQUE RATE LOW
low limit for 1st TORQUE RATe
2ND TORQUE RATE HIGH
HIGh limit for 2nd TORQUE Rate
2ND TORQUE RATE LOW
LOw limit for 2nd TORQUE RATE
3RD TORQUE RATE HIGH
HIgh limit for 3rd TORQUE Rate
3RD TORQUE RATE LOW
Low limit for 3rd TORQUE RAte
Chapter 7: System Operation
Page 7-18