beautypg.com

FEC AFC1200 User Manual

Page 18

background image

)(& ,QF

(standard operating method)

YIELD METHOD
(CW/CCW)

Yield Control method

SPEED CHANGE TORQUE

Shiftpoint from 1st Step to torque speed

THRESHOLD 1 TORQUE

Start of 1st TORQUE RAte measurement

THRESHOLD 2 TORQUE

STart of FINAL ANGLE measurement


1ST TORQUE

SEat torque (1st Torque), end of 1st TORQUE RAte
measurement, start of 2nd TORQUE Rate measurement



CROSSOVER RATE 2

END of 2nd TORQUE Rate measurement, start of 3rd torque

TORQUE

Rate measurement

2ND TORQUE

TORque for 2nd Step in multi-step fastening

3RD TORQUE

TORque for 3rd Step in multi-step fastening

STD TORQUE

FINal target torque in TORQUE Control mode, end of 3rd
TORQUE RAte measurement

HIGH TORQUE

HIgh torque limit

LOW TORQUE

LOw torque limit

HIGH ANGLE

HIGh final angle limit

LOW ANGLE

LOw final angle limit

INCREMENT ANGLE

Preset angle for INTEGRATED TORQUE Rate

1ST TORQUE RATE HIGH

High limit for 1st TORQUE RAte

1ST TORQUE RATE LOW

low limit for 1st TORQUE RATe

2ND TORQUE RATE HIGH

HIGh limit for 2nd TORQUE Rate

2ND TORQUE RATE LOW

LOw limit for 2nd TORQUE RATE

3RD TORQUE RATE HIGH

HIgh limit for 3rd TORQUE Rate

3RD TORQUE RATE LOW

Low limit for 3rd TORQUE RAte

Chapter 7: System Operation

Page 7-18