FEC AFC1200 User Manual
Page 81

)(& ,QF
3rd Rate Low
TL
3rd Rate High
TH
Calibration
CA
2nd Rate Low
SL
Zero
ZE
2nd Rate High
SH
Current
CU
1st Rate Low
FL
RS232 Input #1
RS04
1st Rate High
FH
RS232 Input #1
RS03
Elongation
EL
RS232 Input #1
RS02
Elongation (Angle)
EA
RS232 Input #1
RS01
Final Angle
FA
Final Time
TF
Final Torque
FT
1st Time
T1
Peak Torque
PT
Data Type
Code
Data Type
Code
Data Type (DD) Identification Codes
3-16a. To manually stop data collection, move the cursor on the menu bar to [STOP] and
depress the [
↵
] key. The [DATA COMPLETE] message will appear in the sampling
status window.
3-17a. The data will be collected in *.prn files in the following type of format:
SUBGROUP SIZE = 3
"02/08/95" "14:23:14" "0000001" 37.5 37.6 37.5
"02/08/95" "14:24:32" "0000004" 37.6 37.6 37.5 NUMBER OF
"02/08/95" "14:25:16" "0000007" 37.6 37.5 37.5 GROUPS = 5
"02/08/95" "14:26:40" "0000010" 37.5 37.5 37.5
"02/08/95" "14:23:20" "0000013" 37.6 37.6 37.6
3-18a. To print out the DATA FILE Utility screen, move the cursor on the menu bar to
[PRINT] and depress the
[↵]
key.
B. FILE FORMAT : FREE FORMAT (Data collection is based on System Configuration (1)
screen setup, Header and Line Format area data items)
3-1b.
Refer to the NOTES at the beginning of this Section for information common to both
data file formats. Verify that the System Configuration (1) screen Header Format and
Line Format areas are set-up. Ensure that the data items chosen are the same items
required for the data file. Refer to Section 7.9.7 for information on this setup.
3-2b.
When data item setup is complete, go to the Data File Utility screen. If the data is
being compiled on a diskette, then first insert a formatted diskette into the Floppy Disk
Drive (FDD). Depress the [SEL] key and the cursor will highlight the [DRIVE] field.
USE the
[←]
[→]
3-3b.
After selecting the desired drive, use the alphanumeric pulldown menu to enter the
[PATH] and [FILE NAME] information. [PATH] must be either left blank, or set to an
existing directory name. When performing data file operations, the System will always
reference the root directory first and then the specified path. After entering the
information, select "INPUT END" from the menu and depress the
[↵]
key. The
entered information will appear in the applicable field(s) and the alphanumeric window
will close.
3-4b.
The following Data file utility screen fields have no affect on the data file contents or
format when saving data in Free Format mode:
Spindle Number
Data will be saved for all spindles, regardless of this setup.
Spindle Data
Will save in accordance with ALL, regardless of this setup.
Sub Group Size
Data is saved continuously with no grouping.
Chapter 7: System Operation
Page 7-81