beautypg.com

FEC AFC1200 User Manual

Page 7

background image

)(& ,QF

7.0.4 Standard Operational Procedures

The following items are standard operational procedures utilized throughout the entire
AFC1200 Fastening System program.

1. Initiation of a change in preset data: To initiate a change in the preset data in any of the 15
sections of the AFC1200 program, press the keypad SEL key. The cursor will move from the
Menu bar to the lower portion of the screen. The Run/Program switch must be set to Program
to change fastening presets.

2. Completion of a change in preset data: After all desired changes to the preset data for the
selected screen have been entered, the SEL key must be depressed again. The question
"DATA CHANGE OK ?" will appear in the lower right hand corner of the screen and the

highlighted response will default to NO. To select YES, use the

[←] [→]

keys to move the

highlight. After selecting (highlighting) the appropriate response, depress the

[↵]

key. A YES

selection will update the data to the new entries and a NO selection will result in the loss of all
changes. Refer to Fig. 7-0-4.

FIG. 7-0-4 Data Change Acknowledge

3. Selection of the HELP function: Depress the HLP key to activate the HELP screen. The
HELP screen will display information for the currently active screen. While the HELP screen is
active, the SEL key may be used to toggle between the Operational HELP screen and the
Abnormal (fault) HELP screen. Depress the HLP key again to return to the operational
program.

Chapter 7: System Operation

Page 7-7