beautypg.com

FEC AFC1200 User Manual

Page 20

background image

)(& ,QF

1ST TORQUE

SEat torque (1st Torque), end of 1st TORQUE RATE
measurement, start of 2nd TORQUE Rate measurement

NOTE: EITher 1st tORQUE or 1st angle may set, but not both.

1ST ANGLE

Seat angle (1st angle), end of 1st TORQUE RATE
measurement, start of 2nd TORQUE RATe measurement

CROSSOVER RATE 2

End of 2nd tORQUE Rate measurement, start of 3rd

ANGLE

TORQUE RAte measurement

2ND ANGLE

Angle for 2nd Step in multi-step fastening

3RD ANGLE

Angle for 3rd Step in multi-step fastening

FINAL ANGLE

FINal target angle in ANGLE CONTROL Mode, end of 3rd
TORQUE Rate measurement

HIGH TORQUE

HIGh torque limit

LOW TORQUE

lOw torque limit

HIGH ANGLE

High final angle limit

LOW ANGLE

LOw final angle limit

INCREMENT ANGLE

PREset angle for INTEGRATED TORQUE RATe

1ST TORQUE RATE HIGH

HIgh limit for 1st TORQUE RAte

1ST TORQUE RATE LOW

LOw limit for 1st TORQUE RATe

2ND TORQUE RATE HIGH

HIGH limit for 2nd TORQUE RAte

2ND TORQUE RATE LOW

LOw limit for 2nd TORQUE RAte

3RD TORQUE RATE HIGH

HIgh limit for 3rd TORQUE RATE

3RD TORQUE RATE LOW

LOw limit for 3rd TORQUE RATe

Chapter 7: System Operation

Page 7-20