1. System must be cycled prior to setting [INDICATION SELECT] functions.

2. A minimum of (7) fastening cycles must be completed before the statistics (6 / CPk) are

calculated and displayed.

3. A maximum of 500 cycles of data are stored for each spindle, however the number of

cycles stored varies depending on the number of spindles connected.

1-6 Spindles =

500 cycles per spindle

6-12 Spindles =

250 cycles per spindle

12-18 Spindles =

166 cycles per spindle

18-24 SPINdles = 125 cycles per spindle

4. After the maximum cycles are stored, the next cycle will overwrite the data for the first
cycle.

7.7.5 Stored Data Record

5-1.

To record the stored data move the cursor on the menu bar to [RECORD] using the

[←

←]

[→

→]

keys and depress the

[↵]

key. THe pulldown window will open.

5-2. USe

the

[↑↑↑↑]

[↓↓↓↓]

keys to move the cursor to the desired position for selecting the

following:
[START NUMBER] to set the beginning cycle number of the group to be saved.
[END NUMBER] to set the ending cycle number of the group to be saved.
[DEVICE SELECT] to specify the drive where to save the data. .
[START] to execute the record command. The system will create

an ASCII

Text file giving it a name generated by the date and the time when the recording is
performed, i.e: file 11180120.prn was created on November 18th, at 01:20
[CANCEL] to cancel and exit.

FIG. 7-7-5 stored dATA statistics enable