1. System must be cycled prior to setting [INDICATION SELECT] functions.
2. A minimum of (7) fastening cycles must be completed before the statistics (6 / CPk) are
calculated and displayed.
3. A maximum of 500 cycles of data are stored for each spindle, however the number of
cycles stored varies depending on the number of spindles connected.
1-6 Spindles =
500 cycles per spindle
6-12 Spindles =
250 cycles per spindle
12-18 Spindles =
166 cycles per spindle
18-24 SPINdles = 125 cycles per spindle
4. After the maximum cycles are stored, the next cycle will overwrite the data for the first
cycle.
7.7.5 Stored Data Record
5-1.
To record the stored data move the cursor on the menu bar to [RECORD] using the
[←
←
←
←]
[→
→
→
→]
keys and depress the
[↵]
key. THe pulldown window will open.
5-2. USe
the
[↑↑↑↑]
[↓↓↓↓]
keys to move the cursor to the desired position for selecting the
following:
[START NUMBER] to set the beginning cycle number of the group to be saved.
[END NUMBER] to set the ending cycle number of the group to be saved.
[DEVICE SELECT] to specify the drive where to save the data. .
[START] to execute the record command. The system will create
an ASCII
Text file giving it a name generated by the date and the time when the recording is
performed, i.e: file 11180120.prn was created on November 18th, at 01:20
[CANCEL] to cancel and exit.
FIG. 7-7-5 stored dATA statistics enable
Chapter 7: System Operation
Page 7-55