SPECIFICATIONS
Measurement Ranges
IGNITION
Volts, Battery .......................................... to 20.00 Volts
Volts, Aux (10 Megohm) ...........................
±
20.00 VDC
................. to 50.0 VAC Pk-Pk
Amps - Inductive .........................................
±
600 Amps
Tachometer ....................................... 100 to 5,000 RPM
Dwell, Ignition ............................. Degrees, %, or mSec.
Driver/Points Resistance ............................. to 3.0 Volts
Dwell Variation ............................................ in Degrees
Timing Variation .......................................... in Degrees
Timing Advance ......................................... 90 Degrees
Ignition Coil Amps ....................................... 19.9 Amps
Coil Amps Build Time .................................... 9.9 mSec
Spark Burn Time ........................................... 9.9 mSec
Ignition Energy ............................. 99 milliVolt-Seconds
Secondary KV ............................................ 32 Kilovolts
Pulse Rate (Frequency) ............................... 999 Hertz
Cylinder Power Balance ........................... % RPM Drop
Cylinder Power Contribution ...................... Speed Index
Amps Ripple .................................... Message Indicator
Cranking Compression .......................... % Amps Peak
Injector Amps Drive Time ............................ 99.9 mSec
Injector Peak Amps ..................................... 19.9 Amps
Throttle Position Sensor ......................... Glitch Catcher
O2 Sensor ..................................... Volts and Crossings
Oil Temperature .......................................... 0
°
to 300
°
F
With optional sensors:
Vacuum .......................................................... to 30" Hg
Pressure ......................................................... to 15 PSI
Diesel RPM ...................................... 100 to 5,000 RPM
EMISSIONS
TEST
RANGE
ACCURACY
HC
-
Hydrocarbons
hexane
0 - 2000 ppm
0 - 120
6 ppm
> 120
5% of reading
CO
-
Carbon Monoxide
0 - 10.00 %
0 - 1.2 % 0.06 %
> 1.2% 5% of reading
CO2
-
Carbon Dioxide
0 - 20.0 %
0 - 10 %
0.5 %
> 10% 5% of reading
O2
-
Oxygen
0 - 21.0 %
0 - 2 %
0.1 %
> 2%
5% of reading
NOx
-
Oxides of Nitrogen
0 - 4000 ppm
0 - 1000 ppm range ............................... 32 ppm
1001 - 2000 ppm range ........................ 60 ppm
2001 - 4000 ppm range ...................... 120 ppm
Temperature
5
°
- 150
°
C
.......................... 40
°
- 300
°
F
Vehicle O2 Voltage
0 - 1.2v
DIMENSIONS
Physical
61 x 51 x 145 cm .......... 24 x 20 x 57 inches
Leads
4.3 m
.................................... 14 feet
Sampling Hose
8.5 m
.................................... 28 feet
Operating Temperature
2
°
to 49
°
C 35
°
to 120
°
F
Storage Temperature
-29
°
to 54
°
C .................... -20
°
to 130
°
F
Shipping Weight
80 kg
.................................... 175 lb.
With Gas Analyzer
90 kg
......................................... 200
Power Requirement
12V Vehicle Battery
9-5