beautypg.com

Data recorder – GxT Ferret 54 ENGINE DIAGNOSTIC CENTER User Manual

Page 71

background image

Data Recorder

Emissions or O2 readings can be recorded and played back at any time while viewing the
Composite, Bar Graph, or O2 sensor screens. Press RECORD to begin. To stop or suspend
recording, press PAUSE or RECORD. Press RECORD again to continue.

Each time a recording is started a new section is created, making it easy to isolate separate
events. The NEXT Key is used during Record or Playback to mark events.

To playback recorded data, SELECT

Emissions

or

O2 Sensor

from the FUEL SYSTEM - GAS

ANALYSIS menu. (The O2 test can also be selected from the Sensors menu). If recorded
data is present, this menu will appear:

LIVE - run Emissions

EXAMINE - playback recorded data

PRINT - print recorded data

ERASE - erase then run Emissions

Choose LIVE to display live emissions readings.

To playback recorded data, choose EXAMINE and SELECT a section of data to review. Press
NEXT to begin playback. Pressing FAST FWD once will speed the playback to twice normal
speed. Pressing FAST FWD again will play even faster. Press PAUSE to suspend playback.
REWIND will play the data in reverse.

A memory-used graph indicates how much memory has been used to record readings in record
mode, and where the currently displayed sample is located when in the playback mode.

To print data, choose PRINT, and SELECT a report from the menu:

SELECT Gas Analysis Report

Print Report (Marked Results)

Print Report (All Results)

Print Auto-Test Results

Print all recorded emissions data (all results), or only those events that were marked by pressing
NEXT during Record or Playback mode (marked results). If an AutoTest has been run, you
will be given the option of printing the data that was recorded at the end of the AutoTest. See
the next page for a sample report with detailed descriptions.

Choosing ERASE gives these options:

RECORDED DATA AVAILABLE

Erase Emissions Data

Erase O2 Data

Erase Both Sets

6-6