background image

Page 1-17

CHAPTER 1 — GETTING STARTED

Changing a twinax port’s mode, like changing its address, causes the 5250

ALLY to end communication on that address, change the mode, then

reestablish communication on the address, unless the address is currently

in use. The twinax address must timeout before the 5250 ALLY will end

communication on the address.

4 — Twinax Timeout

When the twinax port has stopped using the output port for a user-

configurable period, the 5250 ALLY considers the output port available

for use by the alternate host port. The timeout period should be as short as

possible to prevent too much time from being wasted between print jobs

from the different sources, but not so short that a job from one source

could interrupt a job from the other source.
The following timeout values are available from the 5250 ALLY front

panel. For most twinax hosts, the default value of 5 seconds is fine.

0. 1 second
1. 5 seconds (default)
2. 10 seconds
3. 15 seconds
4. 30 seconds
5. 45 seconds
6. 1 minute

To change the timeout period, press the MODE button on the 5250 ALLY

front panel until the LED reads “4.” After two seconds, the LED will

display an underscore (_). Then press the MODE button until the LED

displays the number of the appropriate timeout period (0-6). After two

seconds, the timeout period will be changed and the unit will return to

Normal Operating Mode.

Configuring the Parallel Out Printer Port

The next step is to configure the PARALLEL OUT PRINTER port. It has a

configuration that specifies the translation table, format information and

PFS codes appropriate for the printer attached to the port.