background image

Ch 2: Installation and Use of Devices

Hitachi PC VisionBase 8450H/R Server

5

2: Installation and Use of Devices

This chapter explains installation sites for the system equipment and basic uses of removable devices.

Notes on Handling

Installation Site

The following table lists environmental conditions for installing the system equipment:

Avoid installing the system equipment in the following locations:

Location exposed to direct the sun light

Location where temperature or relative humidity changes rapidly

Location near a device (such as motor) generating electric noise

Location near a device generating strong magnetic field

Location with much dust and litter

Location with much vibration

Location where corrosive gas is generated such as sulfur dioxide, hydrogen sulfide, chlorine gas, or ammonia

Location without ventilation, such as within a fully enclosed shelf or box

Item

Allowable range

Temperature

10 to 35

°

C [Non-operating: -10 to 43

°

C]

Relative humidity

20 to 80% [Non-operating: 8 to 90%] (avoid condensation)

Max. wet-bulb temperature

27

°

C

Temperature rise gradient

10

°

C/hour (max)

Minimum clearance required

50 cm in front of equipment, 30 cm behind, and 20 cm to the right and left