Configuration
36
Programming Guide
Parameter
Type
Default
CO
Value Range
1.
CO
2.
EXT
3.
Qsig – Master
4.
Qsig – Slave
Description/Function
Specifies the type of each PRI port on a PRI port basis.
Notes
•
When you change the programming data, the status of the
card must be made OUS (Out-of-Service), and then INS (In-
Service).
•
The type of PRI port can be assigned per PRI23 / PRI30 card.
Reference
• 2.1 ISDN Features (F/G)
– Integrated Services Digital Network (ISDN)
– Integrated Services Digital Network (ISDN) Extension
• 3.1 TIE Line Features (F/G)
– TIE Line Service
• 4.7
ISDN Extension Line (P/G)
Parameter
DN
Default
Blank
Value Range
3-4 digits consisting of 0-9 or X
Description/Function
Specifies the DN (Directory Number) for the PRI port.
(Assignable only when "EXT" is specified in "Type" assignment.)
Note
•
"X" can be used as a wild card character which substitutes
any digit in its position. The last one or two digits of DN may
be "X."
Reference
• 2.3
Numbering Plan (P/G)