Panasonic KX-TD500 User Manual
Page 165
Group
Programming Guide
165
Parameter
Security Mode
Default
Trunk
Value Range
1.
None
2.
Trunk
3.
All
Description/Function
Specifies the Security Mode for DISA callers.
(Assignable only when "DISA" is specified in "OGM Type"
programming.)
1.
None (Non security mode)
DISA callers can make both outside and intercom calls via
DISA without restriction.
2.
Trunk (Trunk Security mode)
DISA callers are required to enter a pre-assigned DISA user
code to make outside calls via DISA.
3.
All (All Security mode)
DISA callers are required to enter a pre-assigned DISA user
code to make both outside and intercom calls via DISA.
Reference
• 1.5 Attended Features (F/G)
– Direct Inward System Access (DISA)
Parameter
[DISA built-in Automated Attendant Tables] Dial 0 - Dial 9
Default
Blank
Value Range
3-4 digits consisting of 0-9
Description/Function
Specifies the extension numbers to each DISA built-in Auto
Attendant number.
Both DN of extensions and FDN (Floating Directory Number) of
extension groups, phantom extensions or TAFAS can be specified.
(Assignable only when "DISA" is specified in "OGM Type"
programming.)
Note
•
A DISA caller can call those extensions simply by dialling a
one-digit DISA built-in Auto Attendant number
corresponding to the extension.
Reference
• 1.5 Attended Features (F/G)