Panasonic KX-TD500 User Manual
Page 126
Group
126
Programming Guide
Parameter
Intercept Destination – Day / Night
Default
Blank
Value Range
3-4 digits consisting of 0-9
Description/Function
Specifies the destination extension (3 or 4 digits) for Intercept
Routing feature in both Day and Night modes respectively.
Notes
•
Intercept Routing provides an automatic re-direction of calls
that have not been answered.
•
There are six possible destinations of intercepted call:
(1) An extension, (2) an external pager (TAFAS),
(3) an OGM group, (4) an extension group,
(5) an incoming group, or (6) a phantom extension.
Reference
• 1.11 Transferring Features (F/G)
– Intercept Routing
Parameter
Pause Time before Flash Signal
Default
512 ms
Value Range
1.
None
2.
512 ms
3.
1024 ms
4.
1536 ms
5.
2048 ms
Description/Function
Specifies the pausing time required before sending the Flash
Signal.
Reference
None
Parameter
Max. Dial No. after EFA Signal
Default
0
Value Range
0-32
Description/Function
Specifies the maximum dialling digits allowed after sending EFA
(External Feature Access) signal.
Note
•
If set to "0," the dialling digits can be sent without limit.
Reference
• 1.12 Conversation Features (F/G)
– External Feature Access
• 2.8.2 If a Host PBX is Connected (U/M)