Panasonic KX-TD500 User Manual
Page 26
Configuration
26
Programming Guide
Parameter
Card No.
Default
—
Value Range
XXX : T1 [ XXX : Card No. (101-314)]
Description/Function
Specifies the physical number of the T1 digital trunk card which
you are going to programme.
Reference
• 1.2
Slot Assignment (P/G)
Parameter
Channel Type
Default
Undefined
Value Range
1.
Undefined
2.
LCO
3.
GCO
4.
DID
5.
TIE (E&M)
6.
OPX
Description/Function
Specifies the type of T1 interface per channel.
1.
Undefined: Not assigned
2.
LCO: Loop Start Central Office
3.
GCO : Ground Start Central Office
4.
DID: Direct Inward Dialling
5.
TIE (E&M): TIE Line
6.
OPX: Off Premise Extension
Reference
• 1.3 System Features (F/G)
– T1 Carrier
Parameter
DN
Default
Blank
Value Range
3 - 4 digits consisting of 0-9
Description/Function
Specifies the extension for the T1 port.
(Assignable only when "OPX" is specified in "Channel Type"
setting.)
Reference
• 2.3
Numbering Plan (P/G)