Panasonic KX-TD500 User Manual
Page 105
System
Programming Guide
105
Parameter
28. Trunk hunting mode
Default
Forced
Value Range
1.
Forced
2.
Loop Detection
Description/Function
Specifies the trunk hunting mode.
1.
Forced
The system seizes a trunk line whether or not loop current is
detected from the local CO.
2.
Loop Detection
The system seizes a trunk line after detecting loop current from
the local CO.
Reference
• 3.2
Trunk Group (P/G)
Parameter
29. Card CODEC
Default
Mu Law
Value Range
1.
Mu Llaw
2.
A Law
Description/Function
Specifies the PCM (Pulse Code Modulation) conversion mode of
KX-T96xxx series trunk and extension cards.
Note
•
This setting is required only when XMX (for Mexico) type
KX-T96xxx series trunk and extension cards are installed in
the system. In this case, select "A Law."
Reference
None
Parameter
30. Net CODEC
Default
Mu Law: [HK], A Law: Others
Value Range
1.
Mu Law
2.
A Law
Description/Function
Specifies the type of PCM (Pulse Code Modulation) conversion
mode compatible with the Digital Network to which the system is
connected.
Note
•
The change of this parameter is activated after resetting the
system.
Reference
None