Panasonic KX-TD500 User Manual
Page 309
![background image](/manuals/9374/309/background.png)
DDI / DID
Programming Guide
309
Parameter
Destination – Day / Night
Default
Blank
Value Range
3-4 digits consisting of 0-9
Description/Function
Specifies the DN / FDN (Extension Group, TAFAS, Phantom
Extension, Remote Resource, OGM Group, Incoming Group) and
Other PBX Extension where a DDI / DID call comes in during Day
/ Night mode respectively.
Reference
• 1.5 Attended Features (F/G)
– Direct Inward Dialling (DID)
• 2.4 ISDN Attended Features (F/G)
– Direct Dialling In (DDI)
• 2.3
Numbering Plan (P/G)
– Other PBX 01 – Other PBX 16
Parameter
Name
Default
Blank
Value Range
Up to 10 characters consisting of 0-9, A-Z, a-z or the following
marks: ! # $ %
( ) + , - / : ; < = > ? @ &.
Description/Function
Specifies the name for the destination extension where a DDI / DID
call comes in.
Reference
• 1.5 Attended Features (F/G)
– Direct Inward Dialling (DID)
• 2.4 ISDN Attended Features (F/G)
– Direct Dialling In (DDI)
Parameter
MSN Line No.
Default
Blank
Value Range
Physical number of the trunk port
Description/Function
Specifies the physical number of the trunk port.
This port will be used to forward a call by ISDN Line.
Reference
• 2.5 ISDN Transferring Features (F/G)
– Call Forwarding by ISDN Line